1,571 research outputs found

    Zugzwangs in chess studies

    Get PDF
    Van der Heijden’s ENDGAME STUDY DATABASE IV, HHDBIV, is the definitive collection of 76,132 chess studies. The zugzwang position or zug, one in which the side to move would prefer not to, is a frequent theme in the literature of chess studies. In this third data-mining of HHDBIV, we report on the occurrence of sub-7-man zugs there as discovered by the use of CQL and Nalimov endgame tables (EGTs). We also mine those Zugzwang Studies in which a zug more significantly appears in both its White-to-move (wtm) and Black-to-move (btm) forms. We provide some illustrative and extreme examples of zugzwangs in studies

    Uniqueness in chess studies

    Get PDF
    Van der Heijden’s ENDGAME STUDY DATABASE IV, HhdbIV, is the definitive collection of 76,132 chess studies. In each one, White is to achieve the stipulated goal, win or draw: study solutions should be essentially unique with minor alternatives at most. In this second note on the mining of the database, we use the definitive Nalimov endgame tables to benchmark White’s moves in sub-7-man chess against this standard of uniqueness. Amongst goal-compatible mainline positions and goal-achieving moves, we identify the occurrence of absolutely unique moves and analyse the frequency and lengths of absolutely-unique-move sequences, AUMSs. We identify the occurrence of equi-optimal moves and suboptimal moves and refer to a defined method for classifying their significance

    First international ring trial of ELISAs for Salmonella-antibody detection in swine

    Get PDF
    An international ring trial for Salmonella-ELISAs for swine serology was organized. Twelve laboratories participated and used in-house ELISAs or commercially available kits. In total 47 well-defined sera from various sources, including inoculation studies with Salmonella-strains from serogroups B, C 1, C2, D, and E I, were tested blindfold. The specificity of most ELISAs was satisfactory, but relatively large differences were found between the sensitivities of the tests. It is concluded that international reference samples should be made available to guarantee a minimum level of sensitivity

    Integrability of a conducting elastic rod in a magnetic field

    Full text link
    We consider the equilibrium equations for a conducting elastic rod placed in a uniform magnetic field, motivated by the problem of electrodynamic space tethers. When expressed in body coordinates the equations are found to sit in a hierarchy of non-canonical Hamiltonian systems involving an increasing number of vector fields. These systems, which include the classical Euler and Kirchhoff rods, are shown to be completely integrable in the case of a transversely isotropic rod; they are in fact generated by a Lax pair. For the magnetic rod this gives a physical interpretation to a previously proposed abstract nine-dimensional integrable system. We use the conserved quantities to reduce the equations to a four-dimensional canonical Hamiltonian system, allowing the geometry of the phase space to be investigated through Poincar\'e sections. In the special case where the force in the rod is aligned with the magnetic field the system turns out to be superintegrable, meaning that the phase space breaks down completely into periodic orbits, corresponding to straight twisted rods.Comment: 19 pages, 1 figur

    InP-based two-dimensional photonic crystals filled with polymers

    Get PDF
    Polymer filling of the air holes of Indium Phosphide based two-dimensional photonic crystals is reported. After infiltration of the holes with a liquid monomer and solidification of the infill in situ by thermal polymerization, complete filling is proven using scanning electron microscopy. Optical transmission measurements of a filled photonic crystal structure exhibit a redshift of the air band, confirming the complete filling.Comment: To be published in Appl. Phys. Let

    Diagnostic value of a heart-type fatty acid-binding protein (H-FABP) bedside test in suspected acute coronary syndrome in primary care

    Get PDF
    AbstractBackgroundTo determine the diagnostic accuracy of a rapid heart-type fatty acid-binding protein (H-FABP) test in patients suspected of acute coronary syndrome (ACS) in primary care.MethodsGeneral practitioners included 298 patients suspected of ACS. In all patients, whether referred to hospital or not, ECG and cardiac biomarker testing was performed. ACS was determined in accordance with international guidelines. Multivariate analysis was used to determine the value of H-FABP in addition to clinical findings.ResultsMean patient age was 66years (SD 14), 52% was female and 66 patients (22%) were diagnosed with ACS. The H-FABP bedside test was performed within 24h (median 3.1, IQR 1.5 to 7.1) after symptom onset. The positive predictive value (PPV) of H-FABP was 65% (95% confidence interval (CI) 50–78). The negative predictive value (NPV) was 85% (95% CI 80–88). Sensitivity was 39% (29–51%) and specificity 94% (90–96%). Within 6h after symptom onset, the PPV was 72% (55–84) and the NPV was 83% (77–88), sensitivity 43% (31–57%) and specificity 94% (89–97%). Adding the H-FABP test to a diagnostic model for ACS led to an increase in the area under the receiver operating curve from 0.66 (95% CI 0.58–0.73) to 0.75 (95% CI 0.68–0.82).ConclusionThe H-FABP rapid test provides modest additional diagnostic certainty in primary care. It cannot be used to safely exclude rule out ACS. The test can only be used safely in patients otherwise NOT referred to hospital by the GP, as an extra precaution not to miss ACS (‘rule in’)

    Refinement of the extended crosswise model with a number sequence randomizer : evidence from three different studies in the UK

    Get PDF
    The Extended Crosswise Model (ECWM) is a randomized response model with neutral response categories, relatively simple instructions, and the availability of a goodness-of-fit test. This paper refines this model with a number sequence randomizer that virtually precludes the possibility to give evasive responses. The motivation for developing this model stems from a strategic priority of WADA (World Anti-Doping Agency) to monitor the prevalence of doping use by elite athletes. For this model we derived a maximum likelihood estimator that allows for binary logistic regression analysis. Three studies were conducted on online platforms with a total of over 6, 000 respondents; two on controlled substance use and one on compliance with COVID-19 regulations in the UK during the first lockdown. The results of these studies are promising. The goodness-of-fit tests showed little to no evidence for response biases, and the ECWM yielded higher prevalence estimates than direct questions for sensitive questions, and similar ones for non-sensitive questions. Furthermore, the randomizer with the shortest number sequences yielded the smallest response error rates on a control question with known prevalence

    The ACRA Anatomy Study (Assessment of Disability After Coronary Procedures Using Radial Access): A Comprehensive Anatomic and Functional Assessment of the Vasculature of the Hand and Relation to Outcome After Transradial Catheterization

    Get PDF
    BACKGROUND: The palmar arches serve as the most important conduits for digital blood supply, and incompleteness may lead to digital ischemia when the radial artery becomes obstructed after cardiac catheterization. The rate of palmar arch incompleteness and the clinical consequences after transradial access are currently unknown.METHODS AND RESULTS: The vascular anatomy of the hand was documented by angiography in 234 patients undergoing transradial cardiac catheterization. In all patients, a preprocedural modified Allen test and Barbeau test were performed. Upper-extremity function was assessed at baseline and 2-year follow-up by the QuickDASH. Incompleteness of the superficial palmar arch (SPA) was present in 46%, the deep palmar arch was complete in all patients. Modified Allen test and Barbeau test results were associated with incompleteness of the SPA (P=0.001 and P=0.001). The modified Allen test had a 33% sensitivity and 86% specificity for SPA incompleteness with a cutoff value of >10 seconds and a 59% sensitivity and 60% specificity with a cutoff value of >5 seconds. The Barbeau test had a 7% sensitivity and 98% specificity for type D and a 21% sensitivity and 93% specificity for types C and D combined. Upper-extremity dysfunction was not associated with SPA incompleteness (P=0.77).CONCLUSIONS: Although incompleteness of the SPA is common, digital blood supply is always preserved by a complete deep palmar arch. Preprocedural patency tests have thus no added benefit to prevent ischemic complications of the hand. Finally, incompleteness of the SPA is not associated with a loss of upper-extremity function after transradial catheterization

    Blood sampling at two slaughterhouses and serological screening of salmonella infections in swine using an indirect ELISA

    Get PDF
    The Animal Health Service in the Netherlands is currently investigating Salmonella infections in finishing pigs in the Netherlands. The investigations combine 2 projects: the SALINPORK-project, financed by the European Union, and a national project \u27Speerpunt Salmonella\u27, financed by the Dutch Ministry of Agriculture, Nature management and Fisheries and the Dutch Product Board for Livestock and Meat
    • …
    corecore